Device Settings manage a range of user configuration options for AutoCal V2. Device settings can be accessed via EFILive V8 Scan and Tune software or via the AutoCal V2 menu.
To edit the Device Settings directly on AutoCal V2;
- Hold Next key to activate Advanced Menu while connecting AutoCal V2 to your vehicle or PC.
- Navigate to the [AutoCal Options] menu.
- Use [OK] to select, and [Prev] and [Next] buttons to scroll.
- After all settings have been reviewed/modified; Use the [Prev] button to return to the top of the list and select [Exit] to save changes and return to [AutoCal Options] menu.
AutoCal Options Menu
Option | Description |
Edit Settings Menu | Access a range of editable settings on the AutoCal V2 device (see Edit Settings table for more information). |
Restore Settings | Returns any modification made in the Edit Settings menu options back to factory defaults. |
Set Date and Time | Adjust date and time settings. |
Browse Files | View tune and log files stored on the AutoCal. |
Delete Files | Allows users to delete tune and scan files stored on the AutoCal V2. |
Free Space | Displays used and available space on the AutoCal V2. |
Format File Sys | Formats the data file system, deleting all scan and tune files stored on the AutoCal V2. |
Edit Settings Menu
Option | Description |
Set Pro Menu | Yes for Advanced Menu, No for Simple Menu. |
Set File # | Set the sequence number for the next AutoCal generated file name. |
Set Locale | Locale USA or Locale Non-USA. |
Set Units | Metric or Custom. |
Set MRU PIDs | Load Most Recently Used PID’s. Set to Yes or No. |
Set Scan Rate | Manage Logging Speed. Set to Fast, Medium or Slow. |
Set CAN Baud | Set CAN speed. |
Set Note 30 | Automatically add “Note 30’ to log file when log file is paused/resumed using [OK]. Set to Yes or No. |
Set Fast CAN | Use EFILive's FAST CAN Mode for flashing. This option can make flash speeds twice as fast on CAN controllers. |
Set Skip Vfy | Skip PID validation prior to starting BBL. Set to Yes or No. |
Set Vfy BBR | Perform extended verification of uploaded file. Set to Yes or No. |
Set BBXStats | Display OBDII retry statistics after Read/Flash is complete. Set to Yes or No. |
Set BBX Dir | Display folders when selecting tune files for flashing. Set to Yes or No. |
Set Switches | Activates switchable tuning on simple menu. Set to Yes or No. |
Set Trace | Automatically save trace file for read/flash errors. Set to Yes or No. |
Set COM Port | Set the device connected to serial port. Supported devices are Wide Band O2, External, or Unknown. |
Set WO2 Type | Select the type of Wide Band device connected to serial port*. |
Set WO2 Fmt | Set the Wide Band controller configuration. Bank 1, Bank 2, Both. |
Set WO2 Data | Set the Wide Band data display format. |
Set WO2-1 ID | Configure the ID's for multiple ECM AFR wide band controllers. |
Set WO2-2 ID | Configure the ID's for multiple ECM AFR wide band controllers. |
Set Stoich | Set the stoichiometric value for the fuel that is being used. |
Set Lo Power | Set time frame to enable Low Power mode to conserve power when the device remains connected but unused for a set period of time. |
Set Splash | Set splash screen display times. |
Set Alert | Set Display Timeout Alerts in milliseconds. (0 = User must respond to message). |
Set Error | Set Display Timeout Errors in milliseconds. (0 = User must respond to message). |
Set AR Delay | Set the time delay before a key begins to Auto-Repeat in milliseconds. |
Set AR Speed | Sets the time delay between repeated key strokes in milliseconds. |
*Note: AutoCal V2 Device Settings contain serial wide band configuration options. AutoCal V2 does not ship with a serial port. A serial port can be fitted to the circuit board, but doing so will void Warranty.