Skip to main content

V3 Device Settings - Knowledgebase / AutoCal V3 / AutoCal V3 Hardware Configuration - EFILive Service Desk

V3 Device Settings

Authors list

Device Settings manage a range of user configuration options for FlashScan/AutoCal V3.  Device settings can be accessed via  EFILive V8 Scan and Tune software or via the FlashScan/AutoCal V3 menu. 

To edit the Device Settings directly on FlashScan/AutoCal V3;

  1. Connect FlashScan/AutoCal V3 to your vehicle or PC.
  2. Navigate to the [ Options] -> [F1: Setup] menu.
  3. Use ✔  to select, Arrow Keys to scroll, and X to return to the previous menu.

F1: Options Menu

Option

Description

F1: Configuration
Access a range of editable settings on FlashScan/AutoCal V3 (see Configuration table for more information).  

F2: Date/Time

Adjust date and time settings.

F3: Update Boot Block

Use this option to check and update the boot block.


Configuration Menu

Option

Description

Display Theme

Set the color theme for the display.

Font Size

Set the font size for the display.  Font size does not control fonts in balloon boxes.

Locale

Locale USA or Locale Non-USA.

Time Format

Set time to 24 hour or am/pm.

Display Units

Metric or Custom.

Key Repeat Delay

Not yet available.

Key Repeat Speed

Not yet available.

Low Power Time

Not yet available.

Next File Number

Set the sequence number for the next automatically generated file name.  

Add Note on Pause

Automatically add a note to log file when log file is paused/resumed using ✔ . Set to Yes or No.

CAN Baudrate

Set CAN speed.

VPW Speed

Set VPW speed.

LED Mode

Set to Status, Alarm or Off.

COM Port Type

Set the device connected to serial port.    Supported devices are Wide Band O2, External, or Unknown.

Set WO2 Type

Select the type of Wide Band device connected to serial port*. 

Set WO2-1 ID 

Configure the ID's for multiple ECM AFR wide band controllers.

Set WO2-2 ID

Configure the ID's for multiple ECM AFR wide band controllers.

Set Stoich 

Set the stoichiometric value for the fuel that is being used.  
For Innovate’s wide band controllers, the stoich value can’t be set using this option, instead it must be set using Innovate’s Logworks software.

Log Serial PIDs

Log external digital (ie. Wide Band Serial) PIDs.

Load MRU PIDs

Not yet available.

12V Switch Log

Connect 12V to start logging.  Disconnect 12V to stop logging.  Set to Yes or No.

12V Switch Beep

Only active when 12V Switch Log is active. 

Two short beeps indicate start, one long beep indicates stop.  Set to Yes or No. 

Verify BBR

Perform extended verification of uploaded file.    Set to Yes or No.

Check BBX Space

Check available BBX space before copying files.  Set to Yes or No.

Save Trace Files

Automatically save trace file for read/flash errors.    Set to Yes or No.

GM Fast

Use EFILive’s Fast CAN mode which can make CAN flashing twice as fast.  Set to Yes or No. 

Cummins BBF

Set Cummins flash speed as Unlimited, Fast, or Standard.


F2: File System -> F2: Manage

Option

Description

F1: Delete File
Allows users to delete tune and scan files stored on the FlashScan/AutoCal V3 .

F3: Format File Sys

Formats the data file system, deleting all scan and tune files stored on the FlashScan/AutoCal V3.

F4: File Sys Info
Provides tools to view information about and explore the contents of the FlashScan/AutoCal V3 file system.
Helpful Unhelpful

9 of 16 people found this page helpful

Add a comment

Please log in or register to submit a comment.

Need a password reminder?